8Proper use of wrench on gas control. Unscrew compression fitting from the pilot outlet (Fig. 0000017288 00000 n
I go over how it is Wired, what Voltages you should be reading while the flame is present and the voltages needed for the pilot valve and main gas valve to work correctly. 0000016758 00000 n
(supposedly so they could fix them :yes: ), Cool. Turn the gas control knob counterclockwise. to protect them and prevent gas from leaking, and discourage tampering by untrained people. One Q340A 36-inch thermocouple with adapters and clip. A contractor came by and gave it a crack at it and said it was the gas valve but I'm not confident that that could be the problem as from reading this post, the thermoCOUPLE should be swapped out first before assuming it is the gas valve as it is a more pricey unit to replace. 9. I would verify the valve type - It would either be the SIT 820 or the Honeywell VS8420. 0000026455 00000 n
2 or 3) while you light the pilot burner. (supposedly so they could fix them :yes: ). Remove the pilot adjustment cover screw. 0
Vermont Castings, Majestic Products: DVR33, Window Frame Assembly Should be Removed Before Service Work, Troubleshooting Honeywell Millivolt Valve, Homeowner's Installation and Operating Manual. If so, then the thermocouple or thermopile is generating enough voltage to keep the safety valve open. Thanks for contributing an answer to Home Improvement Stack Exchange! 0000004711 00000 n
If something is wrong with the internal components of the gas valve, the gas valve should be replaced. 0000011066 00000 n
,[Uw-GTk`{LvG*!1li$:,nZeQh.i&. Draw yourself the circuit. Use only your hand to push down the reset button or turn the gas control knob. 0000007638 00000 n
This includes a WIRING DIAGRAM. At least having yours done professionally would appear to put you in a position of a tax deduction for repairing it. Wiring terminal block color-coded beige to identify standing pilot models. Do not bend tubing at gas control or pilot burner after compression fitting has been tightened, as this may result in a gas leakage at the connection. If you smell gas, immediately shut off the manual valve in the gas piping to the appliance or, on LP, at the tank. IMPORTANT: The specifications given in this publication do not include normal manufacturing tolerances. wc [0 kPa] to rated output pressure within 3-6 seconds (for an 80,000 Btuh furnace at 7 in. Place gas control knob in PILOT position. pressure drop for straight-through configuration). The three-position manual gas control knob has ON, OFF, and PILOT positions. Straight-through body pattern; right-angle adapters available for inlet and outlet. Connect control circuit to gas control terminals. Usually this problem can be resolved by using an adapter. If you have not I will give some ideas. Maintenance frequency must be determined individually for each application. 0000068133 00000 n
Do not force the gas control knob. If the O-ring is not attached or is missing, do not use the flange. Ensure the O-ring is fitted into the groove of the flange. 0000005594 00000 n
0000002780 00000 n
Push in firmly to lock in place. For the VR4200, make sure the conduit cover is in position and secured to the gas valve with the screw provided. But it has been reliable for a long time. As for the gas valve it is probably a "general controls" valve but any 800 millivolt gas valve can be used as a replacement. When the pilot goes out or becomes too small to sustain normal ignition. 0000007857 00000 n
Dont touch any electrical switch or use the phone. Since these environments can cause the gas control to deteriorate more rapidly, the system should e checked more often. A normal reading will be in the range of 145 to 195 millivolts. By clicking Post Your Answer, you agree to our terms of service, privacy policy and cookie policy. To check for gas pipe leaks, put soap on the pipe connecting to the valve, if it bubbles, it means there's leakage. 0000001836 00000 n
By creating an account you agree to the Hunker, How to Light the Pilot Light on a Honeywell VR8200. Outlet pressure to the main burner increases gradually from 0 in. It looks like this: the thermopile is a generatorputs out up to 400 MV. See Fig. 0000015409 00000 n
Home and Building ControlHoneywell Inc.1985 Douglas Drive NorthGolden Valley, Minnesota 55422, Home and Building ControlHoneywell LimitedHoneywell Limite740 Ellesmere RoadScarborough, OntarioM1P 2V9, This is a legacy product document supported by Resideo. The gas control must be manually reset. https://www.trutechtools.com/?affid=43 Use our Promo Code: \"acservicetech\" for 8% off your order! This material is proprietary to Honeywell Limited and shall not be reproduced, copied or used in any manner without prior written consent of . If the appliance uses LP (bottled) gas, be sure to smell next to the floor because LP gas is heavier than air. Also found in certain gas space heaters and construction-site portable heaters. Refer to Fig. If the inlet pressure is in the normal range (refer to Table 7 or 8), replace the existing gas control. 1/2 in. CHECK AND ADJUST GAS INPUT TO THE MAIN BURNER, Standard-Opening and Slow-Opening Pressure Regulator, Step-Opening Pressure Regulator and Delayed and Step-Opening Pressure Regulator. 0000139236 00000 n
Good info, thanks! Is it correct to use "the" before "materials used in making buildings are"? Troubleshooting Honeywell Millivolt Valve, Troubleshooting the Gas Control System, Troubleshooting the Gas Control System, Vermont Castings, Majestic Products: DVR33, SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 00. Mount gas control high enough above cabinet bottom to avoid exposure to flooding or splashing water. Advertisement Order number, SUPER TRADELINE or TRADELINE if desired. Avoid locating gas control where exposure to corrosive chemical fumes or dripping water are likely. To convert control from one gas to another: INSTALL ADAPTERS TO GAS CONTROLIf adapters are to be installed on the gas control, mount them as follows: USING ADAPTERS TO SOLVE SWING RADIUS PROBLEMSIn some field service applications, it is difficult or impossible to thread the gas control onto the gas supply pipe because of space limitations. Gas control is a safety device. THIS SHORTS VALVE COIL AND MAY BURN OUT THE ANTICIPATOR IN THE THERMOSTAT. Inlet and outlet pressure taps included; both taps accessible from the top of gas control. Cover gas control if the appliance is cleaned with water, steam, or chemicals to avoid dust and grease accumulation. Force or attempted repair can result in fire or explosion. Ensure the main burner lights smoothly and without a flashback to the orifice and that all ports remain lit. Thermostat and gas control main burner gas flow.NOTE: Gas controls are shipped with the gas control knob in the ON position. 1/4-inch male quick-connect terminals for electrical connections. There is a heat anticipator coil in there which limits current to the valve, and shorting that out can damage the valve. Do not try to light any appliance. Tis the season. Robertshaw low profile millivolt gas valve- http://amzn.to/2iLXzEhWhite Rodgers 750mv thermopile- http://amzn.to/2zhKVnFRobertshaw pilot and thermopile combo-http://amzn.to/2zZAH8wHoneywell 750mv thermopile- http://amzn.to/2yfR9UKThermopile and Millivolt Gas Valve Troubleshooting Video-https://youtu.be/riaN_j5tmX4Thermopile Testing- https://youtu.be/63zFDe6P1bkWater Heater Thermopile and Millivolt Gas Valve Troubleshooting- https://youtu.be/RASBzK_XF2kHere are some of the Tools I use:Yellow Jacket Refrigerant Gauge Set http://amzn.to/2aenwTqRefrigerant hoses with valves http://amzn.to/2aBumVIYellow Jacket Gauge set \u0026 hoses https://amzn.to/2vLVkV9Yellow Jacket 4 Port Manifold w Hoses https://amzn.to/2BkuGIqFieldpieceSMAN360 Digital Manifold Set https://amzn.to/2BdoaD4FieldpieceSMAN460 Digital Manifold Set https://amzn.to/2nB4Fe6Compact Ball Valve for Refrigerant Hose https://amzn.to/2KUisW8QuickDisconnect 90 for refrigerant hose https://amzn.to/2MMtVcgUEI DL479 Multimeter with temp sensor http://amzn.to/2jtsUbJJB 6 CFM Vacuum Pump http://amzn.to/2nqbvo8Appion Blue 3/8\" to 1/4\" Vacuum Hose http://amzn.to/2uYlVycAppion Red 3/8\" to 1/4\" Vacuum Hose http://amzn.to/2uYg6RoAppion Valve Core Removal Tool http://amzn.to/2uYr8WLYellow Jacket 1/4\" by 1/4\" hose http://amzn.to/2umtcodCPS Vacuum Micron Gauge http://amzn.to/2v1nM3OSupco Vacuum Micron Gauge http://amzn.to/2v1JRiARectorSeal Bubble Gas Leak Detector http://amzn.to/2ckWACnUEI DL389 Multimeter http://amzn.to/2xAdaJfFieldpiece ST4 Dual Temp Meter http://amzn.to/2wc1ME3Air Acetylene Torch setup http://amzn.to/2aQalsb 15% Silver Brazing Rods http://amzn.to/2gVLyLcNitrogen Regulator http://amzn.to/2bXdR5fNitrogen Flow Meter http://amzn.to/2brvoBgDigital Refrigerant Scale http://amzn.to/2b9oXYl Accutrak VPE Ultrasonic Leak Detector https://amzn.to/2nFYKVeImperial Kwik Charge 535-C http://amzn.to/2uipEI6 FieldpieceSDMN6 Dual Manometer Pump http://amzn.to/2jyK5KaSupco Magnet Jumpers http://amzn.to/2gS4h6z2 pairs of alligator clips- http://amzn.to/2CtIL5zJB Vacuum Pump Oil http://amzn.to/2mGrlXyGeneral Tools digital Psychrometer http://amzn.to/2cSHsi1Fieldpiece SDP2 Digital Psychrometer http://amzn.to/2nniMVRRatcheting Service Wrench http://amzn.to/2dGV4NhAppion G5 Twin Recovery Pump http://amzn.to/2dGSEyr Irwin Wire Stripper/Cutter/Crimper http://amzn.to/2dGTj2VShop through Amazon! )POWER UNIT:Hold-in current: 300 mA maximum.Drop-out current: 250 to 90 mA.THERMOCOUPLE:Nominal output: 30 mV (0.018 ohms).Open Circuit Turndown Voltage: 2 mV.ELECTRICAL CONNECTIONS (2): 1/4 inch male quick-connects. For push-in clip-type pilot burners: From beneath, insert the tip of the Q340 into the hole or barrel of the pilot burner. One more troubleshooting tip, on a residential gas furnace if a gas valve is not "clicking" meaning it's apparently not receiving 24 volts you can jump directly off of the control board using the R and the C terminals, R to one terminal on gas valve and C to the other terminal on gas valve (or wherever else you can retain 24 volts from) to the gas valve. Attempted disassembly or repair may damage the gas control. 0000052168 00000 n
[10 to 13 mm] of the thermocouple tip. Where the cost of an unexpected shutdown would be high, the system should be checked more ften. Support horizontal pipes every 3 (91 cm) with metal pipe straps. I was just wondering about this the other day. trailer
<<
/Size 335
/Info 243 0 R
/Encrypt 246 0 R
/Root 245 0 R
/Prev 536170
/ID[]
>>
startxref
0
%%EOF
245 0 obj
<<
/Type /Catalog
/Pages 242 0 R
>>
endobj
246 0 obj
<<
/Filter /Standard
/R 2
/O (__LD98yc0\r!)
/U (\rUob!Yd2U/>6q6)
/P -44
/V 1
>>
endobj
333 0 obj
<< /S 97 /Filter /FlateDecode /Length 334 0 R >>
stream
Your system is quite old and somewhat unsafe, in that the pilot comes off ahead of the safety valve. For a better experience, please enable JavaScript in your browser before proceeding. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION. 2, 3 and 11, 12. 0000057714 00000 n
Use a wrench on the square ends of the gas control. Good Reading Bad Reading Gas valves are not serviceable; the following are simple troubleshooting and description of how gas valves operate. Use new, properly reamed pipe free from chips. If the pilot flame goes out, turn the gas control knob clockwise, If the pilot flame remains lit, turn the gas control knob counterclockwise. 0000028639 00000 n
Thanks. If it isn't flowing, replace the SmartValve. hbbd``b`~@q3` A@e:X
2 D !HWX m 40d# $
? The gas valve is the load.need to have current flow from one leg of the thermopilethrough the limit switch ( zero ohms ) througn the thermostat switch ( approx zero ohms on call for heat) through the coil of the valveand back to the other terminal of the generator. Identify/troubleshoot this millivolt furnace valve, We've added a "Necessary cookies only" option to the cookie consent popup. Proper gas valve adjustment can save your home from a devastating fire. 0000010874 00000 n
0000017061 00000 n
Supervision is needed by a licensed HVACR Tech while doing this as Experience and Apprenticeship garners Wisdom and Safety.Tool List- https://www.amazon.com/shop/acservicetechSupport- https://www.patreon.com/acservicetechWe've Partnered with TruTechTools.com! The second automatic valve diaphragm, controlled by the servo pressure regulator, opens and adjusts gas flow as long as the system is powered and the pilot is burning. Do I need a thermal expansion tank if I already have a pressure tank? This increases gas pressure under the automatic valve and repositions the valve disc closer to the seat. Pilot gas flows through a port in the ushing around the reset button shaft to the pilot burner. There must be two terminals in this connector block that powers the gas valve coil. Follow these warnings exactly: CAUTIONNever apply a jumper across or short the valve coil terminals. 0000003926 00000 n
If tubing is used, ensure the ends are square, deburred and clean. In replacement applications, locate the gas control in the same location as the old gas control. Apply a moderate amount of good quality pipe compound to bushing, leaving two end threads bare. 0000062529 00000 n
As the pressure inside the gas control and underneath the automatic valve diaphragm equalizes, spring pressure closes the second automatic valve to provide a second barrier to gas flow. It has been obsolete for over 30 yrs now. See Fig. Fig. All adjustments, wiring connections, and pilot outlets are accessible from the top of the gas control. 2 or 3) clockwise. If resistance is outside of specifications listed, the gas valve must be replaced. Hold each tester wand on the multimeter to one of the terminals on the gas valve. Resistance between THTP & TP must be 10.0 W 0.2 W Set your thermostat to under the room's current temperature and let at least one minute pass to allow the appliance to attempt to get fuel. Your problem seems to involve large -- really large -- "industrial size" issues. Gas valve troubleshooting looks for a problem. LP to natural gas conversion kit available for standard and slow-opening models. Release button; the pilot should remain lit. Do not force the gas control knob. . PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. Check if gas is flowing if you turn on the gas and the pilot burner doesn't light. I am trying to diagnose a problem with an old furnace. 0000041802 00000 n
If pilot burner flame still goes out, measure the open and closed thermocouple output voltage. Rear V ented Direct V ent Gas Fireplace Model: PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE. The servo pressure regulator monitors outlet pressure to provide n even the main burner gas flow. Both should be under cap screws. startxref
In many such applications, particularly commercial cooking, the equipment operates 100,000-200,000 cycles per year. 0000060666 00000 n
Locate gas control in a well-ventilated area. 0000001377 00000 n
0000002167 00000 n
Standard Opening Pressure Regulation (VR8200A,M, and VR4200A, M)During the ON cycle, the servo pressure regulator provides close control of outlet pressure, even if inlet pressure and flow rate vary widely. (See Fig. See Fig. If it goes out, repeat steps 36. If it is flowing, measure the voltage between the 24V Hot and 24V Common leads to the SmartValve. Turn the gas control knob (Figs. 0000057737 00000 n
Allow the appliance to run through one complete cycle to ensure that the controls are functioning in the correct manner. The first automatic valve is closed. The pilot must be manually relit when normal burner operation is desired. Residential and Building Controls Division Customer Satisfaction. A. Thermocouple-Only: Found in: Most gas log sets with standard safety pilot knob control. Come join the discussion about tools, projects, builds, styles, scales, reviews, accessories, classifieds, and more! If another gas leak is detected, tighten adapter screws, joints, and pipe connections. A forum community dedicated to Do it yourself-ers and home improvement enthusiasts. See Table 3. an Elbow (angle) flange cannot provide a right-hand inlet when the ECO connector is used.NOTE: Flange Kits include one flange with attached O-ring and four mounting screws. Both pilot and main burner are shut off. 0000013062 00000 n
See Table 1 for model specifications.SUPPLY VOLTAGE:VR4200: 120 Vac, 60 Hz.VR8200: 24 Vac, 60 Hz. 0000001116 00000 n
0000027369 00000 n
With O-ring facing the gas control, align the screw holes on the gas control with the holes in the flange. I have some pictures to help clarify what I have, a ThermoPILE system. There must be two terminals in this connector block that powers the gas valve coil. mention that I got the main burner to light on 2 occassions by tapping on either the gas pipe before the main shutoff valve, or on the honeywell gas millivolt valve itself. 0000049228 00000 n
If a gas leak is detected, tighten the pipe connection. the robertshaw link gives max lengths vs. gauge. 0000007879 00000 n
It only takes a minute to sign up. Wait five minutes to allow any gas in the combustion chamber to vent. 0000006141 00000 n
With the . As with the millivolt system, you'll be testing a series of components to locate the faulty part. Circuit Millivolt Check Symptom - Intermittent shutdown or main burner will not light with on/off switch. rev2023.3.3.43278. With the main burner in operation, paint all pipe joints (including adapters) and gas control inlet and outlet with rich soap and water solution. If the knob or reset button will not operate by hand, replace the control using a qualified service technician. Tighten only 1/4 turn beyond finger tight to give good electrical continuity. Install the Q340A asfollows: Connect ThermocoupleConnect thermocouple lead as shown in Fig. Connect the other end of the tubing to the pilot burner according to pilot burner manufacturer instructions. TABLE 6MAXIMUM LENGTH OF SUPPLEMENTARY LIMIT LEADWIRES WHEN USING Q309A THERMOCOUPLE. There should not be a flame-up there if the valve is working correctly. Use an ac voltmeter to measure the voltage across terminals TH and TR. The low-pressureregulator maintains outlet pressure at the preset step rate for several seconds. 0000018745 00000 n
If above 11 ohms, replace the gas control. This decreases gas pressure under the second automatic valve diaphragm and repositions the valve disc further from the seat. Did this satellite streak past the Hubble Space Telescope so close that it was out of focus? Insert bushing in gas control and thread pipe carefully into bushing until tight. I would not work on it, without completely replaceing the gas control system, and the furnace may not be worth that expense. Most common. Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuation in gas supply pressure. I would recommend replacing all the wiring and controls and the pilot generator. These controls combine a manual gas cock, automatic pilot safety valve and a millivolt operator. When the thermostat calls for eat, the first automatic valve and the second automatic valve operator are energized. 0000003581 00000 n
See Accessories.CAPACITY: 130 feet 3 /hour [4.2 meters 3 /hour]. Stand clear while lighting the main burner to prevent injury caused by hidden gas leaks, which could cause flashbacks in the appliance vestibule. The Honeywell Home trademark is used under license from Honeywell International Inc. . PERFORM GAS LEAK TEST WARNING!FIRE OR EXPLOSION HAZARDS CAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH.Check for gas leaks with rich soap and water solution any time work is done on a gas control. If you'd like to support the site, please allow ads. If it fires, it is working correctly. I have a Superior Gas Fireplace model DR-500CMP that currently has a Honeywell Millivolt Gas Valve that I need to replace but the part number does not cross to a valid number. Please comment and ask for videos that you would like to see in the future! I forgot to mention that I got the main burner to light on 2 occassions by tapping on either the gas pipe before the main shutoff valve, or on the honeywell gas millivolt valve itself. How to tell which packages are held back due to phased updates, Short story taking place on a toroidal planet or moon involving flying. Is it possible to rotate a window 90 degrees if it has the same length and width? Bulk update symbol size units from mm to map units in rule-based symbology. These Videos are all part of our Training Series on HVACR Service, Installation, Preventative Maintenance, General Knowledge, and Tips. 2). I show you how to Light the Pil. IF THE PILOT BURNER FLAME GOES OUT WHEN THE GAS CONTROL KNOB IS RELEASED, IF THE MAIN BURNER WILL NOT COME ON WITH A CALL FOR HEAT. How do you ensure that a red herring doesn't violate Chekhov's gun? Square off and remove burrs from the end of the tubing. Fig. DO NOT JUMPER THESE TERMINALS. Free shipping for many products! OD tubing. TROUBLESHOOTING MILLIVOLT GAS VALVES PART # 023625 (NATURAL) & 023624 (LP) TroubleMillvoltGasV 04/16 . 0000010088 00000 n
1. If necessary, adjust the pressure regulator to match the appliance rating. %%EOF
ny outlet pressure change is immediately reflected back to the pressure regulator diaphragm, which repositions to change the flow rate through the regulator valve and, thus, through the diaphragm-operated automatic valve. Lv 4. This product was the perfect replacement for the Honeywell thermopile in a circa 1975 gas fireplace unit. WHEN THE CALL FOR HEAT ENDSWhen the call for heat ends, the first automatic valve and the second automatic valve operator close, bypassing the regulator(s) and hutting ff the main burner. When the ow pressure regulator is fully open, the high-pressure regulator maintains the desired full-rate outlet pressure as described for the standard regulator.The step model requires approximately 60 seconds to reset once the main burner goes off. Tubing installation must comply with approved standards and practices. Assure the main burner primary air supply is properly adjusted for complete combustion (refer to the appliance manufacturer instructions). The maintenance program should include regular checkout of the gas control, see the Startup and Checkout section, and the control system as described in the appliance manufacturer literature. Refer to Fig. 0000002189 00000 n
The automatic pilot safety is separate from the gas cock and provides gas shut Off in case of pilot Outage. Regulator adjustment is accessible from top of gas control.MOUNTING: Can be mounted 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.TEMPERATURE RATING:VR8200A,C,H,J; VR4200A,C,H: 0 F to +175 F [-18 C to +79 C].VR8200M,P; VR4200M,P: -40 F to +175 F [-40 C to +79 C]. The combination of spring pressure under the second automatic valve diaphragm and the lack of outlet pressure holds the diaphragm firmly closed. 0000016504 00000 n
Below are my tests: Ensure the ambient temperature does not exceed the ambient temperature ratings for each component. 0000026478 00000 n
%%EOF
Your email address will not be published. See Fig. ' b1?T3/0.!0s.2c7oDp!c{|87*G2s>y~O9SNF. When the pilot remains lit, turn the gas control knob counterclockwise. Loss of power closes the automatic valves, but leaves the pilot lit, ready to return to normal service when power is restored. This may burn out the heat anticipator in the thermostat. Jumping between the TP/TH and TH does NOT turn the main burner on. Use only glass approved by Vermont Castings, Majestic Products on this fireplace. When the gas control knob is manually turned to OFF. Remove the regulator cap screw and pressure regulator adjusting screw.
Filter. To adjust the pilot flame: LIGHT MAIN BURNERFollow the appliance manufacturer instructions or set the thermostat setting above room temperature to call for heat. White-Rodgers, Honeywell, and other valves makers will usually have it pre-set to that 3.5 wc, some installers forget . 0000042992 00000 n
We might be able to do something about it. Where these instructions differ from the appliance manufacturer, follow the appliance manufacturer instructions.All wiring including 1/4 in. Check the wiring between the thermocouple and the gas control valve operator. Therefore, this unit may not exactly match the listed specifications. This is How to Wire the Thermopile to The 750mv Gas Valve for the Pilot and Main Gas Burners. Assure the main gas supply valve is open and the pilot gas supply line is purged of air. Models for natural or LP gas. Troubleshooting the valve and looking for known common issues will give you peace of mind by ensuring the safe operation of your Honeywell appliance. After installation is complete, use these instructions to check out product operation. Check the regulator setting either with a manometer or by clocking the gas meter. trailer
rating 1/2 psi [3.5 kPa] inlet pressure.PRESSURE REGULATION: See Table 1. Read the safety information in the WARNING.This appliance has a pilot burner, which must be lit by hand. Readjust the full rate outlet pressure if necessary to improve light off characteristics. Loss of pilot flame or flame too small to reliably light the main burner closes the safety shutoff valve and the second automatic valve. VR8200J has a six-second delay from when the thermostat calls for heat until the main gas valve opens. IF THE MAIN BURNER IS OVERFIRINGAdjust the gas control pressure regulator to the correct pressure. Standard-, slow- and step-opening models available. Replace the thermocouple if voltages are outside the acceptable range. 15. Your local Honeywell Residential and Building Controls Sales Office (check white pages of your phone directory). ADJUST THE PILOT BURNER FLAMEThe pilot flame should envelop 3/8 to 1/2 in. If outlet pressure begins to fall, the pressure regulator diaphragm moves slightly lower allowing ore to flow to the gas control outlet. When the pilot goes out, the thermocouple current drops and the power unit drops out, closing the safety shutoff valve. For use in standing pilot appliances. 0000011045 00000 n
Locate the hot surface igniter and look for a spark or glow there. The VR8200 Continuous Pilot Dual Automatic Valve Combination Gas Controls are used in gas-fired, standing pilot appliances. Zero clearance sleeve is only required for combustible walls. the manual gas control knob is in the ON position. Turn off the gas supply valve to your appliance to test whether your valve is capable of shutting down properly. 4 41
0000055329 00000 n
This valve is only for vent free applications. This type of gas valve used a single thermocouple. Is there a solution to add special characters from software and how to do it.